Related Experiment Video
Updated: Nov 4, 2025

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Illuminant metameric effects on interbrand and intrabrand color differences of direct composite resins
Ioannis Brokos1, Nick Polychronakis2, Gregory Polyzois3
1Private practice, Rhodes, Greece; Invited researcher, Division of Cariology and Endodontology, University Clinics of Dental Medicine (CUMD), University of Geneva, Geneva, Switzerland.
Statement Of Problem:
Information on the illuminant metameric effects on the intrabrand and interbrand differences in color of direct composite resins is lacking.
Purpose:
The purpose of this in vitro study was to evaluate the effects of different illuminations on the color differences of the same or different brands of composite resins.
Material And Methods:
Sixty-four disks were prepared from 8 different direct dental composite resins of A3 shade, and, after polymerization and hydration for 48 hours, their color coordinates were measured in the Commission Internationale de I'Eclairage (CIE) L∗a∗b∗ color space with a portable colorimeter on a black and white background under D65 (daylight), F2 (cool white fluorescence), and A (incandescence) illuminations. Translucency parameters (TP) and fluorescence intensities (FI) of the brands were also measured to assist in the interpretation of brand behavior under the illuminations. The Kruskal-Wallis and Friedman nonparametric tests with post hoc multiple comparisons tests were applied to analyze the data for differences within and between brands under all illuminations (α=.05), while regression analysis was used to estimate the relationship between D65 and F2 or A illumination data.
Results:
Statistical analysis showed significant differences among brands (P<.05) for all color coordinates under all illuminations, with a strong linear relationship between them (R2=0.72-0.97). Intrabrand differences were significantly different across brands (P<.05) and ranged from 0.06 to 3.1 across illuminations in ΔE∗ab units (0.05 to 2.4 in ΔΕ00 units). Interbrand differences were also significantly different (P<.05), with a range of 0.15 to 8.7 ΔE∗ab units or 0.14 to 5.7 ΔΕ00 units.
Conclusions:
Primary color coordinates of composite resins were affected by A or F2 illumination and were strongly associated with D65 values. Redder or yellower composite resins were affected more under A or F2 illumination. Intrabrand differences, although small, may contribute to clinical mismatches under A or F2 illuminations. Clinicians should be aware that certain brand pairs may present acceptable differences under D65 illumination but could become unacceptable under A or F2 illumination.
Related Concept Videos
Changes in Skin Color: Clinical Perspectives
Albinism
Albinism is a genetic disorder that affects (completely or partially) the coloring of skin, hair, and eyes. The defect is primarily...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Color Vision
Indicators
Photoreceptors and Visual Pathways
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...

