Purpose:
To investigate the effect of minidental implant location on strain distributions transmitted to tooth abutments and dental minidental implants under mandibular distal extension removable partial denture.
Materials And Methods:
A mandibular Kennedy Class I distal extension model missing teeth 35-37 and 45-47 was constructed. Six dental mini-implants were placed at positions A, B, and C, where position A was 6.5 mm distal to the abutment teeth with 5 mm between each position. Fourteen uniaxial strain gauges were bonded on the model at the region of dental mini-implant and abutment (first premolar). Four groups were designated according to the location of the mini-implants. A load of 150 N and 200 N was applied using an Instron testing machine. Loadings consisted of bilateral and unilateral loading. Comparisons of the mean microstrains among all strain gauges in all situations were analyzed.
Results:
Variation in mini-implant locations induced local strains in different areas. Strains at the tooth abutment were significantly decreased in the group in which implants were placed mesially. Strains around the mini-implants showed different patterns when loaded with different loading conditions. The group in which implants were placed distally showed the lowest strains compared to other groups.
Conclusion:
Mesially placed mini-implants showed the lowest strain around abutment teeth, while a distally-placed mini-implants presented the lowest strain around mini-implants themselves. Under favorable biting force, mini-implant is an option to assist mandibular distal extension removable partial denture. Mesially placed mini-implants are recommended when the abutment has periodontally compromised conditions and a distally placed mini-implant when periodontal conditions are stable.