Related Experiment Video
Updated: Jun 19, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
High Flow Oxygen Therapy at Two Initial Flow Settings versus Conventional Oxygen Therapy in Cardiac Surgery Patients
Stavros Theologou1, Eleni Ischaki2, Spyros G Zakynthinos2
1Department of Cardiac Surgery, Evaggelismos General Hospital, 10675 Athens, Greece.
Abstract:
In cardiac surgery patients with pre-extubation PaO2/inspired oxygen fraction (FiO2) < 200 mmHg, the possible benefits and optimal level of high-flow nasal cannula (HFNC) support are still unclear; therefore, we compared HFNC support with an initial gas flow of 60 or 40 L/min and conventional oxygen therapy. Ninety nine patients were randomly allocated (respective ratio: 1:1:1) to I = intervention group 1 (HFNC initial flow = 60 L/min, FiO2 = 0.6), intervention group 2 (HFNC initial flow = 40 L/min, FiO2 = 0.6), or control group (Venturi mask, FiO2 = 0.6). The primary outcome was occurrence of treatment failure. The baseline characteristics were similar. The hazard for treatment failure was lower in intervention group 1 vs. control (hazard ratio (HR): 0.11, 95% CI: 0.03-0.34) and intervention group 2 vs. control (HR: 0.30, 95% CI: 0.12-0.77). During follow-up, the probability of peripheral oxygen saturation (SpO2) > 92% and respiratory rate within 12-20 breaths/min was 2.4-3.9 times higher in intervention group 1 vs. the other 2 groups. There was no difference in PaO2/FiO2, patient comfort, intensive care unit or hospital stay, or clinical course complications or adverse events. In hypoxemic cardiac surgery patients, postextubation HFNC with an initial gas flow of 60 or 40 L/min resulted in less frequent treatment failure vs. conventional therapy. The results in terms of SpO2/respiratory rate targets favored an initial HFNC flow of 60 L/min.
More Related Videos
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Cardiopulmonary Resuscitation II: ACLS Airway Management