Related Experiment Video
Updated: Nov 3, 2025

Determining Tribocorrosion Rate and Wear-Corrosion Synergy of Bulk and Thin Film Aluminum Alloys
Published on: September 11, 2018
Effect of Martensite Volume Fraction on Oxidative and Adhesive Wear
Yunbo Zhang1, Abdeljalil Jourani1
1FRE UTC-CNRS 2012 Roberval, Université de Technologie de Compiègne, Alliance Sorbonne Université, Centre de Recherche Royallieu, CS 60 319, CEDEX, 60 203 Compiègne, France.
Abstract:
It is generally known that microstructure can considerably affect the tribological behavior of non-lubricated rubbing. However, there is still a lack of awareness about the effect of microstructure on oxidative wear. The present study focused on the effect of martensite volume fraction (MVF) on oxidative wear by using 25CD4 dual-phase steel. Dry friction tests were performed on a ball-on-flat tribometer with a normal load of 15 N and a mean sliding velocity of 0.013 m/s. Friction coefficient and wear rate increase with the increasing MVF. SEM observation and EDXS analyses of the wear scars showed that the oxidation increases with decreasing MVF. For lower MVF, the main wear mechanism is mild oxidative wear. For higher MVF, severe adhesion is predominant as a wear mechanism. The size of the debris decreases with decreasing MVF.
Related Concept Videos
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Oxidation of Alkenes: Syn Dihydroxylation with Osmium Tetraoxide
Oxidation of Alkenes: Anti Dihydroxylation with Peroxy Acids
Radical Oxidation of Allylic and Benzylic Alcohols
Frictional Force
Oxidation of Alkenes: Syn Dihydroxylation with Potassium Permanganate