Re-Sterilisation of Single-Use Telemetric Devices
Leonie Zieglowski1, Anna M Kümmecke2, René H Tolba2
1Institute for Laboratory Animal Science and Experimental Surgery, RWTH Aachen University, Faculty of Medicine, Aachen, Germany, lzieglowski@ukaachen.de.
Abstract:
Implantable telemetric transponders for contactless measurement of physiological parameters are often used in animal-based research. After explantation, single-use devices cannot be re-implanted because of non-validated functionality and necessary re-sterilisation. This is disadvantageous because the battery life would enable a second implantation cycle in another animal. To save costs and time taken for the manufacturer's refurbishing process, we validated and implemented a re-sterilisation protocol for single-use transponders using hydrogen peroxide gas. The described protocol was established with models, i.e., for large (n = 7) and small (n = 3) animals, of telemetric device from 2 different manufacturers (Data Science International and EMKA). All transponders, prepared according to the protocol, were previously implanted subcutaneously in the flank of pigs or rats for a duration of 21 days. Our investigations demonstrate that disinfection only is not sufficient against bacterial contamination and that sterility can only be achieved by additional gas sterilisation with hydrogen peroxide. Furthermore, re-implantation of the re-sterilised transponders into pigs caused neither undesired tissue reactions along the transponder nor impairment of the measured values when compared to the first implantation and after necropsy in 4 cases. We were able to demonstrate that, using our protocol, re-implantation of reprocessed single-use telemetric devices can be performed without compromising transponder quality.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration