Related Experiment Video
Updated: Nov 2, 2025

Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
Biomechanical effect of an occlusal device for patients with an implant-supported fixed dental prosthesis under
Lorena S Silva1, Fellippo R Verri2, Cleidiel A A Lemos3
1Graduate student, Department of Prosthodontics, Presidente Prudente Dental School, University of Western São Paulo - UNOESTE, Presidente Prudente, Brazil.
Statement Of Problem:
Whether providing an occlusal device for a patient with bruxism and an implant-supported fixed dental prosthesis leads to improved biomechanics is unclear.
Purpose:
The purpose of this 3D finite element analysis (FEA) study was to evaluate the biomechanical behavior of 3-unit implant-supported prostheses under parafunctional forces with and without an occlusal device.
Materials And Methods:
Eight 3D models consisting of a posterior (type IV) maxillary bone block with 3 external hexagon implants (Ø4.0×7.0 mm) and 3-unit implant-supported prostheses with different crown connections (splinted or unsplinted) and an occlusal device under functional and parafunctional loading were simulated. The abutment screws were evaluated by von Mises stress maps, and the bone tissue by maximum principal stress and microstrain maps by using a finite element software program.
Results:
An occlusal device improved the biomechanical behavior of the prostheses by reducing stress in the abutment screws and stress and strain in the bone tissue. However, the use of an occlusal device was not sufficiently effective to negate the biomechanical benefit of splinting.
Conclusions:
The use of splinted crowns in the posterior maxillary region with an occlusal device was the most effective method of reducing stress in the abutment screws and stress and strain in the bone tissue when parafunction was modeled.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024