Related Experiment Videos
Neuromagnetic responses from a deaf subject to stimuli presented through a multichannel cochlear prosthesis
R Hari1, M Pelizzone, J P Mäkelä
1Low Temperature Laboratory, Helsinki University of Technology, Espoo, Finland.
Ear and Hearing
|June 1, 1988
Abstract:
Neuromagnetic responses to stimuli presented through a 4-channel cochlear prosthesis were recorded from a deaf subject. The topography of the responses agreed with activation of the supratemporal auditory cortex. The responses to tone pips, noise/square-wave sequences, and to intermittent frequency modulation of a continuous tone resembled those obtained from subjects with normal hearing, being consistent with the good performance of this subject with his implant.