Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
Carlos Palomino-Bautista1, Rubén Sánchez-Jean1, David Carmona-Gonzalez1
1Department of Ophthalmology, University Hospital Quirónsalud, Madrid, Spain.
Abstract:
To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p < 0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r = 0.73, p < 0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Focusing of Light in the Eye
Depth Perception and Spatial Vision
Angle Closure Glaucoma: Treatment