Background And Objectives:
Accurate and regular monitoring of anti-A and anti-B titres pre- and post-transplantation plays a crucial role in the clinical management of patients receiving ABO-incompatible renal transplants. There is no standardized protocol or an external quality assurance program (EQA) currently available for this testing in Australia. The aim of this study was to investigate the diversity of techniques, test platforms and reagents that were currently in use in various laboratories with the aim of developing an EQA.
Materials And Methods:
An online survey was sent to the participants enrolled with the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) to assess their interest in participation in the pilot study. A total of 24 participants who expressed interest were sent the group O plasma, A1 , A2 and B cells to perform ABO titration using their own methods.
Results:
Participants reported a wide range of titre results, from 8 to 1024 for the anti-A titre using A1 cells, from 2 to 128 for anti-A titre using A2 cells and from neat to 32 for anti-B titre using B cells.
Conclusion:
There was a wide variation in titre results between and within different technologies. These findings demonstrate the need for an ABO titration EQA. Development of a standard technique and participation in an EQA program should, over time, reduce variation and enable transferrable results across testing centres, which will assist in consistent clinical interpretation and better outcomes for patients.
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...