Related Experiment Video
Updated: Nov 2, 2025

Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
Comparison of two devices for automated oxygen control in preterm infants: a randomised crossover trial
Hylke H Salverda1, Sophie J E Cramer2, Ruben S G M Witlox2
1Willem-Alexander Children's Hospital, Department of Paediatrics, Division of Neonatology, Leiden University Medical Center, Leiden, Zuid-Holland, The Netherlands H.H.Salverda@lumc.nl.
Objective:
To compare the effect of two different automated oxygen control devices on target range (TR) time and occurrence of hypoxaemic and hyperoxaemic episodes.
Design:
Randomised cross-over study.
Setting:
Tertiary level neonatal unit in the Netherlands.
Patients:
Preterm infants (n=15) born between 24+0 and 29+6 days of gestation, receiving invasive or non-invasive respiratory support with oxygen saturation (SpO2) TR of 91%-95%. Median gestational age 26 weeks and 4 days (IQR 25 weeks 3 days-27 weeks 6 days) and postnatal age 19 (IQR 17-24) days.
Interventions:
Inspired oxygen concentration was titrated by the OxyGenie controller (SLE6000 ventilator) and the CLiO2 controller (AVEA ventilator) for 24 hours each, in a random sequence, with the respiratory support mode kept constant.
Main Outcome Measures:
Time spent within set SpO2 TR (91%-95% with supplemental oxygen and 91%-100% without supplemental oxygen).
Results:
Time spent within the SpO2 TR was higher during OxyGenie control (80.2 (72.6-82.4)% vs 68.5 (56.7-79.3)%, p<0.005). Less time was spent above TR while in supplemental oxygen (6.3 (5.1-9.9)% vs 15.9 (11.5-30.7)%, p<0.005) but more time spent below TR during OxyGenie control (14.7 (11.8%-17.2%) vs 9.3 (8.2-12.6)%, p<0.05). There was no significant difference in time with SpO2 <80% (0.5 (0.1-1.0)% vs 0.2 (0.1-0.4)%, p=0.061). Long-lasting SpO2 deviations occurred less frequently during OxyGenie control.
Conclusions:
The OxyGenie control algorithm was more effective in keeping the oxygen saturation within TR and preventing hyperoxaemia and equally effective in preventing hypoxaemia (SpO2 <80%), although at the cost of a small increase in mild hypoxaemia.
Trial Registry Number:
NCT03877198.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...