Impact of different nebulisers' connections on aerosol therapy
Mona A Abdelrahman1, Mohamed E Abdelrahim1, Haitham Saeed1
1Clinical Pharmacy Department, Faculty of Pharmacy, Beni-suef University, Beni-suef, Egypt.
Background:
Aerosol therapy has the advantage of a higher safety because of the local deposition of inhaled medication to the lung; however, the main drawback is the low and variable amount of delivered drug to patients. Hence, this study aimed to investigate the effect of different accessory connections on aerosol delivery from different nebulisers.
Method:
This study consisted of 3 main models: in vitro, in vivo and ex vivo models. In vitro model, 6 nebulisers (3 Jet (Dolphin (2030 2001), Philips (SideStream) and Tylenol (TL009002)) and 3 vibrating mesh nebulisers (VMNs) (Aerogen Pro, Solo, an Nivo)) were charged with 5 mg/2 mL salbutamol and connected to 2 different connections (T-piece and Circulaire II Hybrid) with an inhalation filter attached to a breathing simulator. Inhaled amounts of drug (inhalation filter) and that remained inside nebuliser were measured. Concerning ex vivo and in vivo models, 24 subjects were involved in the study and they received 5 mg/2 mL salbutamol from 1 Jet nebuliser and 1 VMNs using both connections. Two urine samples were collected post 30 minutes and pooled 24 hours urine collection. For the ex vivo model, inhaled amounts of salbutamol were collected on filters placed between the subjects and the nebuliser.
Results:
Inhaled amounts of salbutamol expressed by the amount of drug detected on inhalation filters (for both in vitro and ex vivo) were significantly higher from both Jet and VMNs connected to the Circulaire II Hybrid connection than that released from nebulisers connected to T-piece. VMNs delivered a higher amount compared with jet nebulisers. The amount released from jet nebulizers were variables, unlike VMNs. Regarding in vivo results, amounts of drug detected in 30 minutes urine samples were consistent with in vitro and ex vivo models reflecting higher and significant amounts of drug delivered to the patient's lung for Circulaire II Hybrid connection compared with T-piece regarding both nebulisers.
Conclusion:
Using a valved chamber with jet and VMNs significantly improved the inhaled amount of the emitted aerosol. VMNs were more effective than jet nebulisers with both connections.
More Related Videos
Related Concept Videos
Inhaled Medications
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes: