Nickel Hypersensitivity to Atrial Septal Occluders: Smoke Without Fire?
Anastasios Apostolos1, Maria Drakopoulou1, Stamatios Gregoriou2
1First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.
Abstract:
Nickel is one of the most common contact allergens worldwide; it is used as the main component of the devices used for atrial septal defects (ASDs) and patent foramen ovale (PFO) closure. Developing nickel hypersensitivity after PFO/ASD occlusion is significantly rarer described in medical literature than typical nickel contact sensitization. The exact pathophysiological mechanism of this "device syndrome" remains unknown, and many question the real incidence or even the existence of this clinical entity. Nevertheless, it has been associated with a wide spectrum of symptoms, including chest pain, migraines, palpitation, and dyspnea. Skin patch tests are the first-line approach to diagnose nickel hypersensitivity. However, diagnostic criteria for the device syndrome have not been developed, and diagnosis in reported cases is established by a process of elimination. Management-drug therapy (corticosteroids, clopidogrel, etc.) or even surgical explantation in severe cases-of patients developing such clinical manifestations after percutaneous PFO/ASD occlusion is empirical. Undoubtedly, endocardiac device-related nickel hypersensitivity requires more focused research to discover the underlying mechanism as well as to develop reliable prognostic tests for detecting high-risk patients and preventing severe nickel hypersensitivity reactions.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
Allergic Drug Reactions
Aortic Regurgitation III: Medical Management
Cardiac Catheterization IV: Nursing Management
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...