Related Experiment Video
Updated: Nov 2, 2025

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
The Standard Point-of-Care Hemochron Jr. ACT+ Test in Monitoring Heparin Administration for Cardiopulmonary Bypass in
Tiina Erkinaro1, Janne Moilanen1, Jarmo Lahtinen1
1Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Finland.
Coagulation factor XII (FXII) is a plasma serine protease that belongs to the contact activation complex responsible for initiating the intrinsic coagulation pathway. FXII deficiency is a rare congenital disorder that is not associated with an increased tendency for bleeding. However, as contact activation is impaired in FXII deficiency, both the celite- and kaolin-initiated activated clotting time (ACT) measurements are prolonged markedly, which poses a challenge for anticoagulation monitoring in patients undergoing cardiac surgery. The authors successfully have used the standard Hemochron Jr. ACT+ test, which is activated by silica and phospholipid in addition to kaolin, to monitor anticoagulation for cardiopulmonary bypass in two patients with severe FXII deficiency. The ACT+ test showed low baseline values, increased adequately in response to heparin, and decreased to baseline after protamine. Importantly, there was no abnormal intra- or postoperative bleeding nor any thrombotic complications. Furthermore, in vitro dose-response ACT+ testing of FXII-deficient blood with increasing heparin concentrations supports the use of ACT+ in FXII deficiency.
Coagulation factor XII (FXII) is a plasma serine protease that belongs to the contact activation complex responsible for initiating the intrinsic coagulation pathway. FXII deficiency is a rare congenital disorder that is not associated with an increased tendency for bleeding. However, as contact activation is impaired in FXII deficiency, both the celite- and kaolin-initiated activated clotting time (ACT) measurements are prolonged markedly, which poses a challenge for anticoagulation monitoring in patients undergoing cardiac surgery. The authors successfully have used the standard Hemochron Jr. ACT+ test, which is activated by silica and phospholipid in addition to kaolin, to monitor anticoagulation for cardiopulmonary bypass in two patients with severe FXII deficiency. The ACT+ test showed low baseline values, increased adequately in response to heparin, and decreased to baseline after protamine. Importantly, there was no abnormal intra- or postoperative bleeding nor any thrombotic complications. Furthermore, in vitro dose-response ACT+ testing of FXII-deficient blood with increasing heparin concentrations supports the use of ACT+ in FXII deficiency.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Catheterization II: Right Heart Catheterization
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care