Related Experiment Video
Updated: Nov 2, 2025

Bovine Mammary Gland Biopsy Techniques
Published on: December 23, 2018
Postoperative wound assessment in cattle: How reliable is the back hand palpation?
Ioannis Proios1, Marian Kusenda2, Christian Seiler3
1Clinic for Cattle, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany. ioannis.proios@tiho-hannover.de.
Background:
As part of clinical wound assessment in bovine surgery, discrepancies in skin temperature are evaluated by placing the back of the hand on the area to be examined. Generally, an increased skin temperature at the wound site for a prolonged period is considered as an indicator of impaired wound healing. The aim of this study was to verify the reliability of palpation under bovine practice conditions using laparotomy as an example. Fourteen cows (German Holstein) with a left displacement of the abomasum (LDA) without other severe concurrent diseases were examined preoperatively and once daily for ten days after surgery. The skin temperature of the wound site in the right flank was assessed by palpation, followed by thermographic evaluation using an infrared camera after a 45-min acclimatisation period, under standardised conditions in a closed examination room daily for 10 days.
Results:
All the incisions healed without clinical detectable perturbances. The ambient temperature range during the study period was 7.8 - 24.1 °C. Two groups were retrospectively defined according to the ambient temperature: high ambient temperature (HT group; median: 20.2 °C 25/75 quartile: 18.5 °C / 21.7 °C; n = 6) and low ambient temperature (LT group; 10.8 °C; 9.4 °C / 12.8 °C; n = 8). The temperature differences (Δϑ) between the mean skin temperature of the wound site and a defined reference area cranial to the wound were assessed. A significant negative correlation was found between the ambient temperature (ϑAmb) and Δϑ (r=-0.51; P < 0.001). The Δϑ was postoperatively higher in the cows in the LT group (median of the individual animals 0.8-2.5 °C) than in the HT group (0.1-0.5 °C; P < 0.05). In contrast to the thermographic findings, manual palpation rarely detected local hyperthermia (> 1 °C) at the wound site (sensitivity 0.20; specificity 0.96).
Conclusions:
The infrared thermography provides a more reliable assessment of temperature changes at the wound site in comparison to manual palpation. The ambient temperature markedly affects the extent of local hyperthermia at the wound site.
Related Concept Videos
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Pre-Procedural Guidelines for Assessing Blood Pressure

