Related Experiment Video
Updated: Nov 1, 2025

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Berlin Green Framework-Based Gas Sensor for Room-Temperature and High-Selectivity Detection of Ammonia
Tingqiang Yang1, Lingfeng Gao1, Wenxuan Wang2
1Institute of Microscale Optoelectronics, Collaborative Innovation Centre for Optoelectronic Science and Technology, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Micro-Nano Photonic Information Technology, Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen University, Shenzhen, 518060, People's Republic of China.
Abstract:
Ammonia detection possesses great potential in atmosphere environmental protection, agriculture, industry, and rapid medical diagnosis. However, it still remains a great challenge to balance the sensitivity, selectivity, working temperature, and response/recovery speed. In this work, Berlin green (BG) framework is demonstrated as a highly promising sensing material for ammonia detection by both density functional theory simulation and experimental gas sensing investigation. Vacancy in BG framework offers abundant active sites for ammonia absorption, and the absorbed ammonia transfers sufficient electron to BG, arousing remarkable enhancement of resistance. Pristine BG framework shows remarkable response to ammonia at 50-110 °C with the highest response at 80 °C, which is jointly influenced by ammonia's absorption onto BG surface and insertion into BG lattice. The sensing performance of BG can hardly be achieved at room temperature due to its high resistance. Introduction of conductive Ti3CN MXene overcomes the high resistance of pure BG framework, and the simply prepared BG/Ti3CN mixture shows high selectivity to ammonia at room temperature with satisfying response/recovery speed.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...