Application of On-Line Sorbentless Cryogenic Needle Trap Extraction Coupled with GC-FID for Analysis of Some Organic
Djavanshir Djozan1, Jamal Norouzi2
1Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
Abstract:
An automated sorbentless cryogenic needle trap device (ASCNTD) was developed for the extraction of organic volatile impurities (OVIs) from solid pharmaceuticals prior to their determination by gas chromatography (GC). In this method, a new set up was designed and used to extraction of several OVIs from ceftazidime, ceftriaxone sodium and amoxicillin. For this purpose, a proper amount of the sample was transferred into the extraction vessel. The sample headspace components were started to circulate through a needle with a flow rate of 20 mL min-1. The OVIs were trapped on the inner surface of a needle placed on top of the sample by flowing liquid nitrogen. After a predetermined time, the coiled nichrome resistance wire placed into the hollow ceramic rod was heated and the trapped analytes were desorbed and swept into the GC capillary column using the carrier gas. The effective parameters such as volume of the sample vial, headspace flow rate, extraction temperature and time, and desorption conditions have been investigated. Qualification studies reveal that pyridine (as a degradation product of ceftazidime), methylene chloride, diethylamine, triethylamine, isopropyl alcohol and n-butyl acetate are the main impurities in the studied pharmaceuticals. Detected OVIs were quantitated using external standard method. The obtained relative standard deviation values were <8%, and the limits of detection (LOD) for the detected OVIs were in the range of 1-34 ng g-1.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...