On-Line Sorbentless Cryogenic Needle Trap and GC-FID Method for the Extraction and Analysis of Trace Volatile Organic
Djavanshir Djozan1, Jamal Norouzi2, Mir Ali Farajzadeh1
1Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
Abstract:
In this study, an automated sorbentless cryogenic needle trap device (ASCNTD) coupled with a gas chromatograph (GC) was developed with the aim of sampling, pre-concentration and determination of volatile organic compounds (VOCs) from soil sample. This paper describes optimization of relevant parameters, performance evaluation and an illustrative application of ASCNTD. The ASCNTD system consists of a 5 cm stainless steel needle passed through a hollow ceramic rod which is coiled with resistive nichrome wire. The set is placed in a PVC (Polyvinyl chloride) chamber through which liquid nitrogen can flow. The headspace components are circulated with a pump to pass through the needle, and this results in freeze-trapping of the VOCs on the inner surface of the needle. When extraction is completed, the analytes trapped in the inner wall of the needle were thermally desorbed and swept by the carrier gas into the GC capillary column. The parameters being effective on the extraction processes, namely headspace flow rate, the temperature and time of extraction and desorption were optimized and evaluated. The developed technique was compared to the headspace solid-phase microextraction method for the analysis of soil samples containing BTEX (Benzene, Toluene, Ethylbenzene and Xylene). The relative standard deviation values are below 8% and detection limits as low as 1.2 ng g-1 were obtained for BTEX by ASCNTD.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Volatilization
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....