Related Experiment Video
Updated: Nov 1, 2025

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
A Finite Element Analysis and Circuit Modelling Methodology for Studying Electrical Impedance Myography of Human
Objective:
Electrical impedance myography (EIM) measures bioimpedance over muscles. This paper proposes a circuit-based modelling methodology originated from finite element analysis (FEA), to emulate tissues and effects from anthropometric variations, and electrode placements, on EIM measurements. The proposed methodology is demonstrated on the upper arms and lower legs.
Methods:
FEA evaluates impedance spectra (Z-parameters), sensitivity, and volume impedance density for variations of subcutaneous fat thickness (t f), muscle thickness (t m), and inter-electrode distance (IED), on limb models over 1Hz-1 MHz frequency range. The limbs' models are based on simplified anatomical data and dielectric properties from published sources. Contributions of tissues to the total impedance are computed from impedance sensitivity and density. FEA Z-parameters are imported into a circuit design environment, and used to develop a three Cole dispersion circuit-based model. FEA and circuit model simulation results are compared with measurements on ten human subjects.
Results:
Muscle contributions are maximized at 31.25 kHz and 62.5 kHz for the upper arm and lower leg, respectively, at 4 cm IED. The circuit model emulates variations in t f and t m, and simulates up to 89 times faster than FEA. The circuit model matches subjects measurements with RMS errors and , while FEA does with and .
Conclusions:
We demonstrate that FEA is able to estimate the optimal frequencies and electrode placements, and circuit-based modelling can accurately emulate the limbs' bioimpedance.
Significance:
The proposed methodology facilitates studying the impact of biophysical principles on EIM, enabling the development of future EIM acquisition systems.
Related Concept Videos
Design Example: Frog Muscle Response
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Bode Plots Construction
RLC Series Circuits: Impedance
Thus, the magnitude of the impedance is given by the following equation,
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...