Related Experiment Video
Updated: Nov 1, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma
Ahmed Elbably1, Haytham Rezq1, Mohamed ElDakkak1
1Department of Ophthalmology, Southampton University Hospital NHS Foundation Trust, Southampton, UK.
Purpose:
This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients .
Methods:
The study includes 25 eyes from 24 patients that met the inclusion criteria. All eyes underwent trabeculectomy with the Ologen implant that provides a space with a dynamic and physiological aqueous reservoir system. The operation was considered successful if IOP is <15 mmHg without need of IOP-lowering drops at 18 months of follow-up.
Results:
The target IOP was achieved in 21 out of the 25 eyes (84%), the remaining four eyes all had an IOP of 16 mmHg at 18 months. Short-term complications consisted of seven cases of bleb leakage treated with bandage contact lens and one case of mild choroidal effusion which resolved after observation alone.
Conclusions:
We can conclude that this technique can provide safety, effectiveness and short learning curve for ophthalmology trainees with lower incidence of perioperative and postoperative complications. Further studies may be required to prove stability and long-term efficacy in management of glaucoma patients.