Related Experiment Video
Updated: Nov 1, 2025

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
Flexible Endoscopes: Terminal Sterilization and Impact to Patient Safety
Abstract:
Flexible endoscopes are implicated in deaths from healthcare-associated infections (HAIs), in particular antibiotic-resistant infections. This article analyzes whether terminal sterilization should be required as part of endoscope reprocessing to reduce or eliminate HAIs and thus improve patient safety. Reusable flexible endoscopes are processed to make them ready for clinical use by the processing department of the healthcare facility. Unlike most critical and semicritical medical devices, the final step of processing an endoscope is high-level disinfection and not terminal sterilization. This is because most flexible endoscopes come in contact with mucosal membranes (versus contact with direct blood stream) and cannot withstand sterilization. However, sterilization currently is performed by a small number of U.S. healthcare facilities on reusable flexible endoscopes with the belief that they are safer for use compared to flexible endoscopes that are high-level disinfected. Based on the analysis in this article, terminal sterilization is not a required or necessary step to eliminate HAIs.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...