The role of electroencephalography electrical reference in the assessment of functional brain-heart interplay: From
Diego Candia-Rivera1, Vincenzo Catrambone1, Gaetano Valenza1
1Bioengineering and Robotics Research Center E. Piaggio and the Department of Information Engineering, School of Engineering, University of Pisa, Pisa, Italy.
Background:
The choice of EEG reference has been widely studied. However, the choice of the most appropriate re-referencing for EEG data is still debated. Moreover, the role of EEG reference in the estimation of functional Brain-Heart Interplay (BHI), together with different multivariate modelling strategies, has not been investigated yet.
Methods:
This study identifies the best methodology combining a proper EEG electrical reference and signal processing methods for an effective functional BHI assessment. The effects of the EEG reference among common average, mastoids average, Laplacian reference, Cz reference, and the reference electrode standardization technique (REST) were explored throughout different BHI methods including synthetic data generation (SDG) model, heartbeat-evoked potentials, heartbeat-evoked oscillations, and maximal information coefficient.
Results:
The SDG model exhibited high robustness between EEG references, whereas the maximal information coefficient method exhibited a high sensitivity. The common average and REST references for EEG showed a good consistency in the between-method comparisons. Laplacian, and Cz references significantly bias a BHI measurement.
Comparison With Existing Methods:
The use of EEG reference based on a common average outperforms on the use of other references for consistency in estimating directed functional BHI. We do not recommend the use of EEG references based on analytical derivations as the experimental conditions may not meet the requirements of their optimal estimation, particularly in clinical settings.
Conclusion:
The use of a common average for EEG electrical reference is concluded to be the most appropriate choice for a quantitative, functional BHI assessment.
More Related Videos
13:32Recording Human Electrocorticographic ECoG Signals for Neuroscientific Research and Real-time Functional Cortical Mapping
Published on: June 26, 2012
11:54Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
Published on: January 29, 2018
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...