Delirium Variability is Influenced by the Sound Environment (DEVISE Study): How Changes in the Intensive Care Unit
Ayush Sangari1, Elizabeth A Emhardt2, Barbara Salas3
1Department of Electrical Engineering and Computer Science, Vanderbilt University, 2301 Vanderbilt Place, PMB 351679, Nashville, TN, 37235, USA.
Abstract:
Quantitative data on the sensory environment of intensive care unit (ICU) patients and its potential link to increased risk of delirium is limited. We examined whether higher average sound and light levels in ICU environments are associated with delirium incidence. Over 111 million sound and light measurements from 143 patient stays in the surgical and trauma ICUs were collected using Quietyme® (Neshkoro, Wisconsin) sensors from May to July 2018 and analyzed. Sensory data were grouped into time of day, then normalized against their ICU environments, with Confusion Assessment Method (CAM-ICU) scores measured each shift. We then performed logistic regression analysis, adjusting for possible confounding variables. Lower morning sound averages (8 am-12 pm) (OR = 0.835, 95% OR CI = [0.746, 0.934], p = 0.002) and higher daytime sound averages (12 pm-6 pm) (OR = 1.157, 95% OR CI = [1.036, 1.292], p = 0.011) were associated with an increased odds of delirium incidence, while nighttime sound averages (10 pm-8 am) (OR = 0.990, 95% OR CI = [0.804, 1.221], p = 0.928) and the ICU light environment did not show statistical significance. Our results suggest an association between the ICU soundscape and the odds of developing delirium. This creates a future paradigm for studies of the ICU soundscape and lightscape.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Sound Intensity
Acute Respiratory Failure-III
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...