Related Experiment Video
Updated: Nov 1, 2025

The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
New iodine-based electrochemical advanced oxidation system for water disinfection: Are disinfection by-products a
Chad Verwold1, Alejandro Ortega-Hernandez1, Jillian Murakami1
1University of Calgary, Department of Chemistry, 2500 University Dr. NW, Calgary, AB T2N 1N4, Canada.
Abstract:
A novel electrochemical Advanced Oxidation System (AOS) has been recently developed for water disinfection where iodide is used to generate active iodine species in-situ. However, the presence of iodide during water disinfection can lead to the formation of iodinated disinfection byproducts (I-DBPs), which have been shown to be more cyto- and genotoxic than their chlorinated and brominated analogs. In this study, the formation of DBPs was assessed in ultrapure water, river water and secondary wastewater effluents treated by the AOS. A comprehensive total organic halogen and target DBP analysis was used that included 25 unregulated DBPs, and the total organic halogen (TOX) quantified as total organic chlorine (TOCl), total organic bromine (TOBr), and total organic iodine (TOI). Ultrapure water disinfection only quantified iodoform (TIM) at a maximum concentration of 0.90 ± 0.05 µg/L. River water results show that TOI increase from 1.3 ± 0.3 µg/L before disinfection (t = 0) to a maximum of 3.5 ± 1.1 µg/L. TIM and bromodiiodomethane (BDIM) were the only targeted iodo-trihalomethanes (I-THMs) that were quantified with a maximum total I-THM concentration of 0.44 µg/L. Secondary wastewater effluent disinfection results show that TOI increased from 1.8 ± 0.3 µg/L (t = 0) to a maximum concentration of 35.3 ± 0.3 µg/L. Iodide and iodate were the main iodinated species exiting the AOS system with a iodine recovery of 94-101%. The results from this study show that the AOS formed low levels of iodinated DBPs in treated water sources that are comparable to the levels found in disinfected drinking water and wastewater.
More Related Videos
09:09A Facile Synthetic Method to Obtain Bismuth Oxyiodide Microspheres Highly Functional for the Photocatalytic Processes of Water Depuration
Published on: March 29, 2019
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Factors Affecting Solubility
Coagulation
Ion Exchange
Chemical Agents for Microbial Control
Ion-Exchange Chromatography