High-performance liquid chromatographic determination of aryl N-methylcarbamate residues using post-column hydrolysis
1Division of Contaminants Chemistry, Food and Drug Administration, Washington, DC 20204.
Abstract:
A high-performance liquid chromatographic technique is reported which selectively detects the phenolic moiety of aryl N-methylcarbamates at low nanogram levels. The carbamates are separated on a C-8 column using an acetonitrile-water gradient mobile phase. The eluted carbamates are hydrolyzed in-line by post-column addition of base, which also serves as electrolyte in the electrochemical (coulometric) detection of the resulting phenols. The technique was tested with six carbamates (bufencarb, carbaryl, carbofuran, 3-hydroxycarbofuran, isoprocarb and methiocarb) and four crops (apples, cabbage, grapes and tomatoes). Optimum detector responses and stability for the carbamates were attained at 0.60 V. Detector response to the carbamates in the presence of crop coextractives was 99% of theoretical with a standard deviation of 2.8% at the 0.05- to 0.1-ppm fortification level. The lower limit of quantitation is 0.01 ppm. Other electrochemical detectors were evaluated for suitability for this work.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...