Related Experiment Video
Updated: Oct 31, 2025

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Dynamic force decay evaluation of latex and non-latex orthodontic elastics
Robert Klabunde1, Thorsten Grünheid2
1Division of Orthodontics, School of Dentistry, University of Minnesota, 6-320 Moos Health Science Tower, 515 Delaware Street S.E., 55455, Minneapolis, MN, USA.
Purpose:
To evaluate the force decay over time of latex and non-latex orthodontic elastics subjected to either static or dynamic stretching under simulated intraoral conditions.
Materials And Methods:
Four types of elastics (1/4-inch 4.5 ounces and 1/4-inch 6.5 ounces, each latex and non-latex) were subjected to either static stretching to 3 times internal diameter (ID) or dynamic stretching from 3 to 4.5 times ID in artificial saliva at 37 °C for 24 h. Forces generated by the elastics were measured at 0, 1, 2, 4, 8, 12, and 24 h. Differences among elastic types, time points, and between stretching regimens were tested for statistical significance (P < 0.05).
Results:
Both stretching regimens caused rapid force decay in all elastic types, which was significantly higher in the non-latex elastics than in the latex elastics. In contrast, there were no differences between elastic types made of the same material. With both stretching regimens, the force decay was significant only after the first hour for the latex elastics, whereas it remained significant up to 24 h for the non-latex elastics. All elastic types generated significantly lower forces after dynamic stretching than after static stretching with 70.2, 68.8, and 66.1% of the initial force remaining after 4, 8, and 24 h for latex elastics and 48.0, 40.8, and 29.5% for non-latex elastics.
Conclusion:
Latex elastics retained significantly more force over time than their non-latex equivalents. Because of the higher force decay in a dynamic environment, it is important that non-latex elastics be changed more frequently.
More Related Videos
Related Concept Videos
Elasticity in Concrete
Elasticity
The elasticity of an object can be described by a stress-strain curve, which represents the relationship between stress...
Members Made of Elastoplastic Material
As the bending moment...
Residual Stresses in Bending
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Circular Shafts - Elastoplastic Materials
As torque on the...

