Is the Nox-T3 device scoring algorithm accurate enough for the diagnosis of obstructive sleep apnea?
Margarida Pimenta Valério1, Samuel Pereira2, Joaquim Moita2
1Pulmonology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal. mvalerio@campus.ul.pt.
Introduction:
Obstructive sleep apnea (OSA) is highly prevalent. Home sleep apnea testing (HSAT) for OSA is rapidly expanding because of its cost effectiveness in the diagnosis of OSA. Type 3 portable monitors are used for this purpose. In most cases, these devices contain an algorithm for automatic scoring of events. We propose to study the accuracy of the automatic scoring algorithm in our population in order to compare it with the manually edited scoring of Nox-T3®.
Material And Methods:
For five months, a prospective study was performed. Patients were randomly distributed to the available HSAT devices. We collected the data of patients who performed HSAT with Nox-T3®. We used normality plots, the Spearman correlation, the Wilcoxon signed-rank test, and Bland-Altman plots.
Results:
The sample consisted of 283 participants. The average manual apnea and hypopnea index (AHI) was 23.7 ± 22.1 events/h. All manual scores (AHI, apnea index, hypopnea index, and oxygen desaturation index) had strong correlations with their respective automated scores. When AHI > 15 and AHI > 30 the difference between the values of this index (automatic and manual) was not statistically significant. Also, for AHI values > 15 the mean difference between the two scoring methods was 0.17 events/h. For AHI values > 30, this difference was - 1.23 events/h.
Conclusions:
When AHI is < 15, there may be a need for confirmation of automatic scores, especially in symptomatic patients with a high pretest probability of OSA. But, for patients with AHI > 15, automatic scores obtained from this device seem accurate enough to diagnose OSA in the correct clinical setting.
More Related Videos
04:54Author Spotlight: IntelliSleepScorer — A High-Accuracy, Accessible GUI Software for Automated Sleep Stage Scoring in Mice and its Application in Psychiatric Research
Published on: November 8, 2024
07:31Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...