Related Experiment Video
Updated: Aug 14, 2026

Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
Published on: October 22, 2014
Deep learning-based automated detection for diabetic retinopathy and diabetic macular oedema in retinal fundus
Feng Li1, Yuguang Wang1, Tianyi Xu2
1School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China.
Objectives:
To present and validate a deep ensemble algorithm to detect diabetic retinopathy (DR) and diabetic macular oedema (DMO) using retinal fundus images.
Methods:
A total of 8739 retinal fundus images were collected from a retrospective cohort of 3285 patients. For detecting DR and DMO, a multiple improved Inception-v4 ensembling approach was developed. We measured the algorithm's performance and made a comparison with that of human experts on our primary dataset, while its generalization was assessed on the publicly available Messidor-2 dataset. Also, we investigated systematically the impact of the size and number of input images used in training on model's performance, respectively. Further, the time budget of training/inference versus model performance was analyzed.
Results:
On our primary test dataset, the model achieved an 0.992 (95% CI, 0.989-0.995) AUC corresponding to 0.925 (95% CI, 0.916-0.936) sensitivity and 0.961 (95% CI, 0.950-0.972) specificity for referable DR, while the sensitivity and specificity for ophthalmologists ranged from 0.845 to 0.936, and from 0.912 to 0.971, respectively. For referable DMO, our model generated an AUC of 0.994 (95% CI, 0.992-0.996) with a 0.930 (95% CI, 0.919-0.941) sensitivity and 0.971 (95% CI, 0.965-0.978) specificity, whereas ophthalmologists obtained sensitivities ranging between 0.852 and 0.946, and specificities ranging between 0.926 and 0.985.
Conclusion:
This study showed that the deep ensemble model exhibited excellent performance in detecting DR and DMO, and had good robustness and generalization, which could potentially help support and expand DR/DMO screening programs.