A Flow Cytometry-Based Cell Surface Protein Binding Assay for Assessing Selectivity and Specificity of an Anticancer Aptamer
Published on: September 13, 2022
[Comparison of two capillary electrophoresis methods for aptamer-protein affinity characterization]
Qingwei Meng1,2, Lei Guo1, Jianwei Xie1
1State Key Laboratory of Toxicology and Medical Countermeasures, and Institute of Toxicology and Pharmacology, Academy of Military Medical Sciences, Beijing 100850, China.
Abstract:
Affinity interaction characterization is a prerequisite for understanding the specific binding of nucleic acid aptamers to their target molecules and consequently their appropriate applications. The CE technique provides a simple and multi-mode approach to such a characterization, but different results obtained from multiple modes and systems lead to limited reliability and further applications. Thus, there is an urgent need to develop systematic comparison approaches of multi-mode applications in CE, which would allow a better investigation of the affinity between aptamers and target molecules. In this work, based on CE laser-induced fluorescence detection, we applied the CE frontal analysis (FA) approach for affinity evaluation and compared it with preequilibrium-capillary zone electrophoresis (PE-CZE) using thrombin and its 29-mer aptamer as a model system that specifically binds to the heparin binding site. The optimization conditions of the CE-FA method included 30 s injection of a mixture incubated at 37℃ for 0.5 h followed by separation at low (15℃) working temperature using short capillary (30 cm) under 15 kV in a biocompatible buffer (2×TG, pH=8.5), which provided stable plateau peaks of complex and free fluorescent-labeled 29-mer (F29-mer) aptamers. The addition of 1 g/L bovine serum albumin (BSA) enhanced the reproducibility of the plateau peak heights and migration times during the CE-FA separation. We then discussed in detail the results and features obtained from six fitting modes of the two methods. We applied multiple fitting modes for CE-FA and PE-CZE, including the nonlinear fitting of bound/free aptamer ratio versus free aptamer concentration, non-linear fitting of plateau peak height versus concentrations, and non-equilibrium CE of equilibrium mixtures (NECEEM) calculation. We observed that 5 of 6 fitting results showed no significant difference and all dissociation constant (Kd) values were in the range between 24 and 64 nmol/L. Three fitting modes of the CE-FA approach aligned well with each other, indicating that the association-dissociation equilibrium between the aptamer and complex could be easily maintained under the non-equilibrium CE separation conditions using the CE-FA method, and the measured Kd values were more accurate. Using the PE-CZE method, the Kd fitted from nonlinear regression through free aptamer peak height decrease versus concentration indicated a significant deviation. Moreover, we obtained accurate Kd values from the NECEEM calculation approach by choosing 0.5-2-fold thrombin against F29-mer. This approach allowed the clear observation of an exponential bridge between the two peaks in the electrophoregrams. The CE-FA and PE-CZE methods could be used to mutually confirm each other, improving the affinity evaluation reliability. In this work, we recommend the selection of the CE-FA evaluation method as a priority, with a fitting mode through plateau peak height derived from a series of various concentrations. It could effectively address the problem of the high voltage-affected unstable complex peaks in CE. This provides such advantages that allow wide application, robust use, and feasible and accurate fitting results.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Affinity Chromatography
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Capillary Electrophoresis: Instrumentation