Related Experiment Video
Updated: Oct 30, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Acute Effect of Enhanced External Counterpulsation on the Carotid Hemodynamic Parameters in Patients With High
Yahui Zhang1,2,3, Zhouming Mai1, Jianhang Du1,3
1Department of Cardiology, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, China.
Insights
Enhanced external counterpulsation (EECP) acutely altered carotid hemodynamics, reducing end-diastolic velocity and increasing resistance index. Specific improvements were noted in patients with hyperlipidemia, hypertension, and type 2 diabetes.
Area of Science:
- Cardiovascular Medicine
- Medical Engineering
- Hemodynamics
Background:
- Enhanced external counterpulsation (EECP) is known to improve carotid circulation in coronary artery disease patients.
- The specific hemodynamic responses in carotid arteries of patients with high cardiovascular risk factors undergoing EECP require further investigation.
Purpose of the Study:
- To investigate the acute effects of EECP on carotid artery hemodynamic parameters.
- To analyze these effects in patients with hypertension, hyperlipidemia, and type 2 diabetes, as well as healthy controls.
Main Methods:
- Eighty-three subjects (hypertension, hyperlipidemia, type 2 diabetes, healthy controls) received a 45-min EECP session.
- Doppler ultrasound measured common carotid artery (CCA) hemodynamic parameters: PSV, EDV, ID, VS/VD, FR, and RI.
- Measurements were taken before, during, and immediately after EECP.
Main Results:
- During EECP, all groups showed reduced EDV and VS/VD, and increased RI (P < 0.01).
- Hyperlipidemia patients experienced increased CCA ID and left CCA FR during EECP (P < 0.05).
- Post-EECP, hyperlipidemia patients had higher ID, hypertension patients had higher RI, and type 2 diabetes patients had lower PSV and VS/VD compared to baseline.
Conclusions:
- EECP acutely reduced EDV, PSV, VS/VD and increased RI, FR, and ID in CCAs across all groups.
- A single EECP session yielded immediate improvements in specific hemodynamic parameters for patients with hyperlipidemia, hypertension, and type 2 diabetes.
- Tailored EECP strategies may be guided by these differential hemodynamic responses in patients with distinct cardiovascular risk factors.
Purpose:
Enhanced external counterpulsation (EECP) can improve carotid circulation in patients with coronary artery disease. However, the response of carotid hemodynamic parameters induced by EECP in patients with high cardiovascular risk factors remains to be clarified. This study aimed to investigate the acute effect of EECP on the hemodynamic parameters in the carotid arteries before, during, and immediately after EECP in patients with hypertension, hyperlipidemia, and type 2 diabetes.
Methods:
Eighty-three subjects were recruited into this study to receive 45-min EECP, including patients with simple hypertension (n = 21), hyperlipidemia (n = 23), type 2 diabetes (n = 18), and healthy subjects (n = 21). Hemodynamic parameters in both common carotid arteries (CCAs) were measured and calculated from Doppler ultrasound images. Peak systolic velocity (PSV), end-diastolic velocity (EDV), mean inner diameter (ID), systolic/diastolic flow velocity ratio (VS/VD), flow rate (FR), and resistance index (RI) were monitored before, during, and immediately after 45-min EECP.
Results:
EDV and VS/VD were significantly reduced, while RI of CCAs was significantly increased among four groups during EECP (all P < 0.01). Additionally, the ID of CCAs and the FR of left CCA increased in patients with hyperlipidemia during EECP (P < 0.05). PSV of left CCA was reduced in patients with type 2 diabetes (P < 0.05). Moreover, immediately after EECP, ID was significantly higher in patients with hyperlipidemia. The RI of patients with hypertension and PSV and VS/VD of patients with type 2 diabetes were significantly lower compared with baseline (all P < 0.05).
Conclusion:
EECP created an acute reduction in EDV, PSV, and VS/VD, and an immediate increase in the RI, FR, and ID of CCAs among the four groups. Additionally, a single 45-min session of EECP produced immediate improvement in the ID of patients with hyperlipidemia, the RI of patients with hypertension, and the PSV and VS/VD of patients with type 2 diabetes. The different hemodynamic responses induced by EECP may provide theoretical guidance for making personalized plans in patients with different cardiovascular risk factors.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Heart Failure Drugs: β-Blockers
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse
The pulse serves as a clinical...
Exercise and Cardiac Output