Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Peak Expiratory Flow During Mechanical Insufflation-Exsufflation: Endotracheal Tube Versus Face Mask
Sung Eun Hyun1,2, Sang-Min Lee3, Hyung-Ik Shin4,2
1Department of Rehabilitation Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
Background:
Mechanical insufflation-exsufflation (MI-E) applied through the endotracheal tube (ETT) can effectively eliminate airway secretions in intubated patients. However, the effect of the interface (ETT vs face mask) on expiratory air flow generated by MI-E has not been investigated. This study aimed to investigate the effect of the ETT on peak expiratory flow (PEF) along with other associated factors that could influence PEF generated by MI-E.
Methods:
Intubated participants received 2 sessions of MI-E via ETT therapy per d for 2 consecutive days. One MI-E session consisted of 5 sets of either constant (+40/-40 cm H2O) or incremental (+30/-30 to +50/-50 cm H2O) pressure applications. Following extubation, MI-E sessions were repeated using face mask. Expiratory air flow during MI-E therapy was continuously measured, and every PEF during each application was analyzed using linear mixed-effect and generalized linear mixed models.
Results:
A total of 12 participants (9 [75.0%] men; mean [SD] age, 74.0 [10.2] y) completed all MI-E sessions with both ETT and face mask interfaces. The PEF generated during MI-E treatment was influenced by the interface (ETT vs face mask), pressure gradient, and number of session repetitions. Adjusted mean PEF values for MI-E via ETT and face mask at +40/-40 cm H2O were -2.521 and -3.114 L/s, respectively, and -2.956 and -3.364 L/s at +50/-50 cm H2O, respectively. At a pressure gradient of +40/-40 cm H2O, only 172 of 528 MI-E trials via ETT (32.6%) achieved a PEF faster than -2.7 L/s, whereas 304 of 343 MI-E trials via face mask (88.6%) exceeded PEF < -2.7 L/s.
Conclusions:
MI-E via ETT generated slower PEF than via face mask, suggesting that a higher-pressure protocol should be prescribed for intubated patients. An insufflation-exsufflation pressure up to +50/-50 cm H2O could be considered to produce a PEF faster than 2.7 L/s, and the applications were safe and feasible for subjects on invasive mechanical ventilation.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...