Current-limiting amplifier for high speed measurement of resistive switching data

T Hennen1, E Wichmann1, A Elias2

  • 1IWE II, RWTH Aachen University, 52074 Aachen, Germany.

Related Concept Videos

Small-Signal Analysis of MOSFET Amplifiers01:23

Small-Signal Analysis of MOSFET Amplifiers

In small-signal analysis, a MOSFET transistor amplifier acts as a linear amplifier when operating in its saturation region. The gate-to-source voltage (VGS) of the MOSFET is the sum of the DC biasing voltage and the small time-varying input signal. This combination sets up the operating point and modulates the drain current (ID) that flows from the drain to the source. When a small AC signal is superimposed on the DC bias voltage at the gate, the instantaneous drain current comprises three...
806
MOSFET Amplifiers01:17

MOSFET Amplifiers

The MOSFET, when operating in its active region, functions as a voltage-controlled current source. In this region, the gate-to-source voltage controls the drain current. This principle underlies the operation of the transconductance MOSFET amplifier. The output current is directed through a load resistor to convert this amplifier into a voltage amplifier. The output voltage is then obtained by subtracting the voltage drop across the load resistance from the supply voltage. This process results...
262
Design Example: Frog Muscle Response01:14

Design Example: Frog Muscle Response

A student is tasked to work on an intriguing experiment involving an RL (Resistor-Inductor) circuit to study the muscle response of a frog's leg to electrical stimulation. The RL circuit plays a crucial role in this experiment, providing the means to control and measure the electrical impulses that trigger muscle contraction.
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
403
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
397