Impurity toroidal rotation profile measurement using upgraded high-resolution visible spectroscopic diagnostic on
G Shukla1, M B Chowdhuri2, K Shah1
1Department of Science, Pandit Deendayal Petroleum University, Gandhinagar 382 007, India.
Abstract:
A high-resolution spectroscopic diagnostic for the measurement of spatial profiles of impurity ion toroidal rotation velocities on the ADITYA-U tokamak has been upgraded to cover the complete plasma minor radius. Earlier, the coverage of diagnostics toward the plasma edge was restricted due to the placement of collection optics on the tangential port outside the vacuum vessel. The coverage of the full plasma minor radius, from 0 to 24 cm, has been achieved using the newly designed and developed collection optics that have seven lines of sight to view the tokamak plasma mounted inside a customized re-entrant view port which is installed in the shadow of the limiter inside the vacuum vessel. The upgraded diagnostic also includes a faster charged coupled device detector with a smaller pixel size for the detection of a small wavelength shift. The complete spatial profile has been measured using the Doppler shifted passive change exchange spectral line at 529.0 nm from the C5+ ion. In this article, we present the collection optics' design, installation, calibration, and results obtained using the upgraded diagnostic.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference