Related Experiment Video
Updated: Oct 29, 2025

Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
Published on: July 2, 2012
Two-color interferometer for study of dense low-ionized plasma on the target in high-power pulse linear accelerator
V V Danilov1, D I Skovorodin1, S S Popov1
1Budker Institute of Nuclear Physics of Siberian Branch Russian Academy of Sciences (BINP SB RAS), 11, Acad. Lavrentieva Pr., Novosibi1rsk 630090, Russian Federation.
Abstract:
A two-color infrared interferometer has been developed for the investigation of high-density weakly ionized tantalum plasma in x-ray complexes based on linear induction accelerators (1.6 kA electron beam current, 4.6 MeV energy, and 100 ns pulse duration). Simultaneous probing at two different wavelengths makes it possible to independently measure the density of neutral and electron components. The interferometer uses wavelength values of 1.064 µm (Nd:YAG laser) and 10.6 µm (CO2 laser). To attenuate the effect of sample beam refraction in inhomogeneous plasma, the interferometer used a refraction suppression scheme composed of spherical mirrors focusing the object beam into the region occupied by the plasma. In addition, the power of the sample beam transmitted through the plasma was controlled in order to analyze whether there was a distortion of the interference pattern because of strong sample beam refraction and absorption in the plasma cloud. To calibrate the initial phase shift of the probe radiation, a movable mirror mounted on a piezoelectric element and oscillating according to a harmonic law with amplitude greater than the laser wavelengths was used. In initial experiments, the parameters of target plasma registered by this interferometer are as follows: the linear density of neutrals reached 1.5 · 1017 cm-2, and the degree of ionization was of the order of 10-2. The target plasma expansion velocity is determined as ∼6 km/s.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Mass Analyzers: Common Types
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences