Quantifying Plant Soluble Protein and Digestible Carbohydrate Content, Using Corn Zea mays As an Exemplar
Published on: August 6, 2018
Simultaneous quantification of total carbohydrate and protein amounts from aqueous solutions by the sulfuric acid
Swen Ehnert1, Jürgen Seehase1, Christine Müller-Renno1
1Department of Physics and Research Center OPTIMAS, University of Kaiserslautern, 67663 Kaiserslautern, Germany.
Abstract:
Based on the sulfuric acid-ultraviolet assay (SA-UV, developed by Albalasmeh et al., 2013), we have further expanded this method for the simultaneous quantification of saccharides (carbohydrates) and proteins by ultraviolet spectrophotometry. The absorbance of saccharides depends on the formation of furfurals by dehydration in the presence of concentrated sulfuric acid, whereas proteins are unaffected and can be quantified by UV active peptide bonds and aromatic amino acid residues. In saccharide/protein mixtures the SA-UV assay offers a good alternative and substitutes the need for two different methods, like the phenol-sulfuric acid (PSA, developed by DuBois et al., 1951) and bicinchoninic acid (BCA, developed by Smith et al., 1985) assays. For the development of this method, we used glucose and BSA as model substrates and performed a method validation in terms of linearity, LOD, LOQ, accuracy, and precision. Simultaneous quantification in glucose/BSA mixtures is possible down to 20 mg/L from 30 μL sample volumes, and even low content mixtures with concentrations down to 2 mg/L can appropriately be quantified from higher volumes by an evaporation technique.
More Related Videos
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...