Related Experiment Video
Updated: Oct 29, 2025

Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation
Published on: July 15, 2015
Machine perfusion of kidney allografts affects early but not late graft function
Navdeep Singh1, April Logan1, Austin Schenk1
1Division of Transplantation, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
Background:
Hypothermic machine perfusion (HMP) parameters are influenced by donor variables which further affect recipient outcome. Interplay between these parameters can help to predict kidney performance on pump and the long term outcome.
Methods:
All the kidneys transplanted at our center between May 2013 through November 2017 were included in the study. Donor and recipient data was obtained from internal database. Multiple logistic regression models with backward selection were used to determine significant donor and pump variables.
Results:
Donor BMI, KDPI, age and donor sex had a significant association with pump flow. Donor sex, donor type, KDPI and age had significant effect on RI. Diastolic pressure and KDPI were significantly associated with DGF. Duration on pump, KDPI, flow, donor creatinine and type of donor were significantly associated with day 5 creatinine. KDPI was significantly associated with Day 365 creatinine.
Conclusion:
HMP effects early graft function while the long term function depends on donor parameters.
Related Concept Videos
Kidney Transplant I: Introduction
Kidney Transplant II: Surgical Procedure