The control effect of 3D spiral wind-curtain generator on respirable dust pollution during tunnelling process
Yun Hua1,2, Wen Nie3,4, Lidian Guo1,2
1College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao, 266590, Shandong Province, China.
Abstract:
The respirable dust pollution produced in the cutting process of tunnelling machine during tunnelling process is a serious threat to the health of workers. The key to solve this problem is to build an effective ventilation system in the tunnel. In this paper, experiments were designed and implemented to obtain the temporal-spatial evolution of respirable dust pollution before and after the 3D spiral wind-curtain generator was used for tunnel auxiliary ventilation, and the CFD method was used to supplement and visualize the experimental results. Before the 3D spiral wind-curtain generator was used, the respirable dust gradually diffused from the cutting face to other spaces of the tunnel, and finally presented a stable state with time. After using the 3D spiral wind-curtain generator for auxiliary ventilation, the dust diffusion speed in the tunnel was slower than before, and the dust concentration was lower than before. When adjusting the position of the generator and installing it 20m away from the cutting face, an effective dust control wind-curtain formed within the range of 3.5 ~ 6.5m away from the cutting face. With the increase of time, the dust is stably controlled within the space of 4.5m away from the cutting face, and then pumped away by the exhaust fan, so as to purify the tunnel environment and ensure the tunnel's cleanliness and safety and efficient excavation.
Related Concept Videos
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Effects of Air-entrainment in Concrete
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...