Maksim Korotun1, Luis Quintero1, Mark Shikowitz2
1Division of Pulmonary, Critical Care and Sleep Medicine, Department of Medicine, Donald and Barbara Zucker School of Medicine at Hofstra-Northwell, Great Neck, NY; and.
Background:
Hypoglossal nerve stimulation (HGNS) is an Food and Drug Administration-approved therapy for obstructive sleep apnea. Initial programming of HGNS is based on the observation of anterior tongue movement, which may not reflect opening at the retroglossal airway. We developed an ultrasonographic technique to assess the base of tongue movement with HGNS to be used to optimize the initial voltage settings.
Study Question:
This study aimed to investigate the use of ultrasound to assess tongue movement with HGNS and related this measure to the apnea hypopnea index (AHI) on subsequent home sleep apnea testing or in-laboratory polysomnography with therapy.
Study Design:
Seventeen subjects (n = 17) implanted with HGNS were enrolled at least 1 month postimplantation. Ultrasonographic measures were then used to optimize HGNS voltage to produce observable base of tongue protrusion without producing discomfort. Responders were defined as a reduction in AHI > 50% and an AHI of <20 events/h.
Results:
There were 17 subjects, 11 men and 6 women, with age = 64.6 ± 9.8 years, body mass index = 27.9 ± 2.7 kg/m2, and pretreatment AHI = 36.5 ± 14.4/h, T-90% = 10.7 ± 14.8%. The mean hyoid bone excursion (HBE) in responders = 1.0 ± 0.13 cm versus 0.82 ± 0.12 cm in nonresponders (P = 0.017). HBE was correlated with AHI during HGNS treatment (coef. -0.54, P = 0.03). Best subsets regression analysis using treatment-based AHI as the dependent variable and age, body mass index, baseline AHI, HBE, and HGNS voltage as independent variables showed that HBE (coef. -44.6, P = 0.044) was the only independent predictor of response. Receiver operator curve analysis showed that HBE > 0.85 cm had a sensitivity of 83.3% and specificity of 80.0% with a positive likelihood ratio of 4.17 to predict responder status.
Conclusion:
We demonstrated that ultrasound assessment of HBE during HGNS programming is a useful tool to optimize therapy.
More Related Videos
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Cranial Nerves: Types Part II
Facial Nerve (Cranial Nerve VII)
Cranial nerve VII, or the facial nerve,...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cardiopulmonary Resuscitation II: ACLS Airway Management