Objective:
Dynamic thiol-disulphide homeostasis is an indicator of the antioxidant system that interacts early with the oxidative environment. This study aimed to assess the dynamic thiol/disulphide balance in individuals with white-coat hypertension (WCH).
Methods:
This cross-sectional study included a total of 117 individuals who presented to our outpatient cardiology clinic. Seventy patients were diagnosed with WCH. All blood samples were obtained from the patients after a minimum of 8 h of fasting, centrifuged immediately, stored in Eppendorf tubes, and protected at -80°C.
Results:
The two groups were well-balanced in terms of age, gender, and BMI. Native thiol and total thiol levels were lower in the WCH group than in normotensive individuals. However, disulphide levels were higher in the former. Serum disulphide concentration positively correlated with 24-h SBP, and 24-h DBP. In backward stepwise logistic regression analysis, serum disulphide [odds ratio (OR) = 1.165 (1.089-1.245), 95% confidence interval (CI), P < 0.001] and serum total thiol levels [OR = 0.992 (0.984-1.000), 95% CI, P = 0.050] were independently associated with WCH.
Conclusion:
We demonstrated that dynamic thiol/disulphide balance shifted strongly towards disulphide formation due to thiol oxidation in patients with WCH.
More Related Videos
07:16Resin-Assisted Capture Coupled with Isobaric Tandem Mass Tag Labeling for Multiplexed Quantification of Protein Thiol Oxidation
Published on: June 21, 2021
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Hypertension II: Pathophysiology
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hypertension I: Introduction
Hypertension and Regulation of Blood Pressure