Related Experiment Video
Updated: Oct 28, 2025

15:00
Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
2.7K
Correction: Continuous Monitoring of Vital Signs Using Wearable Devices on the General Ward: Pilot Study
Mariska Weenk1, Harry van Goor1, Bas Frietman1
1Radboud University Medical Center, Department of Surgery, Nijmegen, Netherlands.
JMIR Mhealth and Uhealth
|July 16, 2021
Abstract:
[This corrects the article DOI: 10.2196/mhealth.7208.].
Related Concept Videos
Pulse rhythm
1.0K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.0K
Holter Monitor: 24-Hour Monitoring
585
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
585
Guidelines For Measuring Vital Signs
2.2K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
2.2K
Introduction to Vital Signs
6.0K
Vital signs are physiological measurements that help key into the status of the body's essential functions. These include body temperature, pulse rate, respiratory rate, and blood pressure, commonly abbreviated as T, P, R, and BP. Some healthcare settings also consider oxygen saturation (SpO2) and, in specific contexts, pain and level of consciousness as additional vital signs.
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
6.0K
Pulse Oximetry
979
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
979
Equipments Used To Measure Blood Pressure
2.7K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.7K

