Related Experiment Video
Updated: Oct 27, 2025

Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
Published on: February 23, 2020
Aerosol Generation in Ear Canal and Air-Fluid Interface Suction
Mohammed Bahgat1, Leon Lindsey1, Paul Lindsey2
1Ear, Nose and Throat Department, Sunderland Royal Hospital, Sunderland, UK.
Objective:
The identification of aerosol-generating procedures (AGPs) is important during the current SARS-CoV-2 pandemic due to aerosol-mediated virus transmission. Aerosol measurement during clinical procedures using particle counting may be confounded by variable natural background aerosol levels or limited by partial volume sampling. The study objective was to quantify any significant aerosol generated from simulated suction clearance procedures.
Study Design:
Prospective quantification of aerosol generation during clinical suction simulation.
Setting:
Clean chamber.
Methods:
We created a clean environment for particle counting in a transparent neutralized polypropylene chamber. Air was passed through a HEPA 14 class filter to maintain a constant chamber inlet pressure. An optical particle counter was connected in line to the chamber exhaust vent to measure all of the vented particles. The chamber background count was 1 particle ≥0.3 µm per 15 minutes at a flow rate of 1 chamber air change per minute. We used this system to quantify very low aerosol counts generated from suction clearance of a silicone ear canal and at an open air-fluid interface.
Results:
No clinically significant aerosol generation was found by particle counting of the whole chamber air volume during simulated suction procedures.
Conclusion:
Simulated ear suction clearance and air-fluid interface suction does not generate any significant aerosol. It appears likely that any aerosol potentially generated at the suction tube tip is entrained by incoming air flow. This is the first study to quantify aerosols generated by suction in a controlled environment; further research is required to determine its clinical implications.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Anatomy of the Ear
Tracheostomy Suctioning II: Procedure