Related Experiment Video
Updated: Oct 27, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Removable Partial Dentures with Polyetheretherketone Framework: The Influence on Residual Ridge Stability
Lucio Lo Russo1, Konstantinos Chochlidakis2, Giammarco Caradonna3
1Department of Clinical and Experimental Medicine, School of Dentistry, University of Foggia, Foggia, Italy.
This study found no significant short-term differences in jawbone changes for patients wearing digital Polyetheretherketone (PEEK) removable partial dentures (RPD) compared to untreated controls. These findings suggest PEEK RPDs do not accelerate bone loss over one year.
Area of Science:
- Dentistry
- Prosthodontics
- Biomaterials Science
Background:
- Edentulous residual ridge resorption is a common challenge in prosthodontics.
- Digital workflows offer potential for improved fabrication of removable partial dentures (RPD).
- Polyetheretherketone (PEEK) is a promising biomaterial for RPD frameworks due to its properties.
Purpose of the Study:
- To compare 1-year dimensional changes in edentulous residual ridges between patients wearing digitally fabricated PEEK RPDs and untreated controls.
- To evaluate the efficacy of PEEK RPDs in preserving residual ridge height and dimensions.
Main Methods:
- A clinical case-control study involving 10 patients with PEEK RPDs and 6 controls.
- Intraoral scans at baseline and 1-year follow-up were analyzed using metrology software.
- Residual ridge height changes (C0-C1 distance) and mean 3D distances were measured and statistically compared.
Main Results:
- No statistically significant differences in residual ridge height changes were observed between the PEEK RPD group (-0.39 ± 0.52 mm) and the control group (-0.52 ± 0.54 mm).
- Mean 3D distances at denture-bearing areas also showed no significant difference between groups (-0.3 ± 0.46 mm vs. -0.4 ± 0.35 mm).
- Confounding variables like follow-up time and alignment accuracy were comparable between groups.
Conclusions:
- This 1-year clinical study indicates no short-term adverse effects on edentulous residual ridge dimensions for patients wearing digitally fabricated PEEK RPDs compared to controls.
- The findings suggest that PEEK RPDs, fabricated via digital workflows, do not exacerbate bone resorption in the short term.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
06:022-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016