Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
Published on: April 25, 2025
Is flow control in a space-constrained drainage network effective? A performance assessment for combined sewer
Wenqi Wang1, João P Leitão2, Omar Wani3
1Department of Hydrosciences, School of Earth Sciences and Engineering, Nanjing University, 210023, Nanjing, China; Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland.
Abstract:
Recurring combined sewer overflows (CSOs) can have a significant impact on the ecological condition of receiving water bodies. There are several structural measures, like adding retention basins and switching to low impact development solutions, that have been proposed to reduce the number of sewage overflows. Besides, several flow control strategies have been discussed in scientific literature that take advantage of the space within urban drainage networks, which is assumed to be adequate, for temporary storage. The adequacy of such storage space, however, is not a universally valid assumption as a large fraction of drainage networks frequently operate close to their design discharge. In this paper, we investigate the efficacy of flow control for a space-constrained drainage network. We employ a low-cost, heuristic real time control strategy with the use of flow control devices (FCDs) and available in-sewer space to reduce the magnitude of CSOs. We consider the performance of the proposed control strategy and discuss the effect of FCD location on CSO reduction. Our results, based on over 300 rainfall-event simulations, show that the flow control strategy using limited sewer capacity is more efficient during relatively small rainfall events, where the CSO is large enough to enable reduction using the chosen control rules. The CSO is reduced, to varying degrees, for around 80% of rainfall events with peak intensity between 10 and 20 mm h-1. For larger rainfall events, the flow control is more unstable in response to abrupt water release during control operation, which seems to be unavoidable because of the water accumulation effect and the transition to pressurized pipe flow in space-constrained networks. We also found that the flow control performance is highly sensitive to the FCD location - as it depends on the interplay of the peak rainfall intensity and the water level condition immediately upstream of the FCD. The efficacy of a location for flow control is determined by the unfilled capacity (i.e., effective in-sewer storage potential) in the pipe upstream of the FCD during the rainfall peak; furthermore, the location also has to be resistant to the water accumulation effect. Using our analysis, we substantiate two anticipated caveats to flow control strategies when the storage space is limited in a drainage network: diminished performance in CSO reduction and the appearance of additional control-related challenges, which are otherwise mitigated in more spacious networks.
More Related Videos
06:26Capturing Flow-weighted Water and Suspended Particulates from Agricultural Canals During Drainage Events
Published on: November 7, 2017
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
Related Concept Videos
Underflow Gates
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Gradually Varying Flow
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...
Laminar Flow
Energy Considerations in Open Channel Flow