Enrichment and Detection of Antigen-Binding B Cells for Mass Cytometry
Related Experiment Video
Updated: Jul 2, 2026

Sample Preparation for Mass Cytometry Analysis
Published on: April 29, 2017
Zachary C Stensland1, Mia J Smith1,2
1Barbara Davis Center for Diabetes, Department of Pediatrics, University of Colorado School of Medicine, Aurora, CO 80045, USA.
Over the years, various techniques have been utilized to study the function and phenotype of antigen-binding B cells in the primary repertoire following immunization, infection, and development of autoimmunity. Due to the low frequency of antigen-reactive B cells (<0.05% of lymphocytes) in the periphery, preliminary enrichment of cells is necessary to achieve sufficient numbers for statistically sound characterization, especially when downstream analytic platform use, e.g., CyTOF, is low throughput. We previously described a method to detect and enrich antigen-reactive B cells from peripheral blood and tissues using biotinylated antigens in conjunction with magnetic nanoparticles, preparative to a downstream analysis by ELISPOT and flow cytometry. While mass cytometry (CyTOF) enables high dimensional immunophenotyping of over 40 unique parameters on a single-cell level, its low throughput compared to flow cytometry and requirement for removal of metal contaminants, such as nanoparticles, made it particularly unsuitable for studies of rare cells in a mixed population. Here we describe a novel CyTOF-compatible approach for multiplexed enrichment of antigen-reactive B cells, e.g., insulin and tetanus toxoid, using cleavable magnetic nanoparticles. This method allows improved monitoring of the phenotype and function of antigen-reactive B cells during the development of disease or after immunization while minimizing the amount of sample and run times needed.
Over the years, various techniques have been utilized to study the function and phenotype of antigen-binding B cells in the primary repertoire following immunization, infection, and development of autoimmunity. Due to the low frequency of antigen-reactive B cells (<0.05% of lymphocytes) in the periphery, preliminary enrichment of cells is necessary to achieve sufficient numbers for statistically sound characterization, especially when downstream analytic platform use, e.g., CyTOF, is low throughput. We previously described a method to detect and enrich antigen-reactive B cells from peripheral blood and tissues using biotinylated antigens in conjunction with magnetic nanoparticles, preparative to a downstream analysis by ELISPOT and flow cytometry. While mass cytometry (CyTOF) enables high dimensional immunophenotyping of over 40 unique parameters on a single-cell level, its low throughput compared to flow cytometry and requirement for removal of metal contaminants, such as nanoparticles, made it particularly unsuitable for studies of rare cells in a mixed population. Here we describe a novel CyTOF-compatible approach for multiplexed enrichment of antigen-reactive B cells, e.g., insulin and tetanus toxoid, using cleavable magnetic nanoparticles. This method allows improved monitoring of the phenotype and function of antigen-reactive B cells during the development of disease or after immunization while minimizing the amount of sample and run times needed.