Related Experiment Video
Updated: Oct 27, 2025

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Risk factors for unplanned extubation in ventilated neonates in South Korea
1Neonatal Intensive Care Unit, Dong-A University Hospital, South Korea.
Purpose:
Although unplanned extubation (UE) is a common occurrence in neonatal intensive care units (NICUs), the factors influencing UE have not been clearly identified in South Korea. Therefore, we investigated the incidence of UE along with its risk factors among neonates in the NICU.
Design And Methods:
This retrospective cohort study was conducted in a single NICU in B city. The electronic medical records of 137 ventilated neonates admitted between January 2017 and June 2018 were analyzed using an audit tool on extubation. Kaplan-Meier estimation and univariate and multivariate Cox proportional hazards models were used for statistical analyses.
Results:
The rate of UE was 32.1%, with an incidence of 6.56 per 100 ventilation days during the 18-month study period. Risk factors for UE were the use of sedatives or analgesics; no re-fixation of the endotracheal tube (ETT); suction frequency; a high nurse-patient ratio; and working night shifts (weekdays 5 p.m. to 8 a.m.), weekends, or holidays.
Conclusions:
The rate of UE among neonates was found to be considerably higher than that of other countries. Among the various factors, nursing-related factors were most commonly associated with the risk of UE.
Application To Practice:
Various prevention strategies, including complete ETT fixation, maintaining ETT placement, a low nurse-patient ratio, and close observation of the ETT may help reduce UE in the NICU.
More Related Videos
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...