Related Experiment Video
Updated: Oct 26, 2025

Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Tricuspid Valve Replacement in a Patient with a Leadless Cardiac Pacemaker: Current Guidelines and Recommendations
River Hames1, J W Awori Hayanga2, Diane Schmidt-Krings3
1West Virginia University School of Medicine, 1 Medical Center Drive, Morgantown, WV 26506, USA.
Abstract:
Leadless cardiac pacemakers were developed to reduce complications associated with conventional transvenous pacemakers. While this technology is still relatively new, devices are increasingly being implanted. The perioperative management of patients with these devices has been underreported; we thus seek to add to the limited body of knowledge of perioperative management of patients with leadless cardiac pacemakers. An elderly female patient with a Micra VR transcatheter pacing system leadless cardiac pacemaker placed for tachycardia-bradycardia syndrome with intermittent complete heart block was scheduled for elective tricuspid valve replacement for severe tricuspid regurgitation. Pacemaker interrogation was performed several hours prior to the scheduled surgery based on the electrophysiologist's availability; the device was kept in its programmed VVIR mode, and the base rate was increased from 60 to 80 beats per minute in anticipation of the upcoming surgery. Upon preoperative evaluation, the anesthesiologist asked that the electrophysiology team be placed on standby intraoperatively due to the concern that either oversensing in the setting of pacemaker dependence and/or undesirable tachycardia from rate-responsive pacing could occur. The surgeon used monopolar electrocautery for the duration of the cardiac surgery. Despite the patient having evidence of pacemaker dependence in the intensive care unit preoperatively, no electromagnetic interference leading to oversensing nor rate modulation was detected during intraoperative electrocardiographic and intraarterial invasive monitoring. Evidence-based guidelines regarding perioperative management specifically of leadless cardiac pacemakers do not exist. As these devices become more prevalent, further evaluation will be paramount to determine whether existing guidelines for perioperative management of conventional transvenous pacemakers apply.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:31A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis III: Medical Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Mitral Regurgitation III: Medical Management
Cardiac Catheterization IV: Nursing Management
Mitral Valve Prolapse III: Nursing Management