Related Experiment Video
Updated: Oct 26, 2025

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Extracorporeal carbon dioxide removal with the Advanced Organ Support system in critically ill COVID-19 patients
Julia Allescher1, Sebastian Rasch1, Johannes R Wiessner1
1Klinik und Poliklinik für Innere Medizin II, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany.
Abstract:
Disturbed oxygenation is foremost the leading clinical presentation in COVID-19 patients. However, a small proportion also develop carbon dioxide removal problems. The Advanced Organ Support (ADVOS) therapy (ADVITOS GmbH, Munich, Germany) uses a less invasive approach by combining extracorporeal CO2 -removal and multiple organ support for the liver and the kidneys in a single hemodialysis device. The aim of our study is to evaluate the ADVOS system as treatment option in-COVID-19 patients with multi-organ failure and carbon dioxide removal problems. COVID-19 patients suffering from severe respiratory insufficiency, receiving at least two treatments with the ADVOS multi system (ADVITOS GmbH, Munich, Germany), were eligible for study inclusion. Briefly, these included patients with acute kidney injury (AKI) according to KDIGO guidelines, and moderate or severe ARDS according to the Berlin definition, who were on invasive mechanical ventilation for more than 72 hours. In total, nine COVID-19 patients (137 ADVOS treatment sessions with a median of 10 treatments per patient) with moderate to severe ARDS and carbon dioxide removal problems were analyzed. During the ADVOS treatments, a rapid correction of acid-base balance and a continuous CO2 removal could be observed. We observed a median continuous CO2 removal of 49.2 mL/min (IQR: 26.9-72.3 mL/min) with some treatments achieving up to 160 mL/min. The CO2 removal significantly correlated with blood flow (Pearson 0.421; P < .001), PaCO2 (0.341, P < .001) and levels (0.568, P < .001) at the start of the treatment. The continuous treatment led to a significant reduction in PaCO2 from baseline to the last ADVOS treatment. In conclusion, it was feasible to remove CO2 using the ADVOS system in our cohort of COVID-19 patients with acute respiratory distress syndrome and multiorgan failure. This efficient removal of CO2 was achieved at blood flows up to 300 mL/min using a conventional hemodialysis catheter and without a membrane lung or a gas phase.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis