Magnet induced elusive ventricular loss of capture in a dual-chamber pacemaker: What is the mechanism?
Debabrata Bera1, Saurabh D Dhumale1, Ayan Kar1
1Department of Cardiology, RTIICS, Kolkata, India.
Journal of Cardiovascular Electrophysiology
|July 27, 2021
Abstract
No abstract available in PubMed .
Keywords:
insulation failuremagnet associated loss of capturemedtronic dual-chamber pacemakerwand-associated capture lossMore Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
15.0K
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
28.1K
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
7.7K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
7.7K
Mechanism of Cardiac Arrhythmias
1.3K
Arrhythmias are irregular heart rhythms occurring when the heart's electrical impulses become abnormal. These disturbances can lead to various symptoms, depending on their severity and the underlying cause. Some common factors contributing to arrhythmias include hypoxia, ischemia, electrolyte imbalances, excessive catecholamine exposure, drug toxicity, and muscle overstretching. Arrhythmias can be classified into two main types based on the rate and site of origin of abnormal heart rhythms.
1.3K
Magnetic Damping
654
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
654
Cardiac Action Potential
3.8K
Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
3.8K
Conduction System of the Heart
11.0K
Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
11.0K