Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Investigating the impact of the CT Hounsfield unit range on radiomic feature stability using dual energy CT data
Avishek Chatterjee1, Martin Valliéres2, Reza Forghani3
1McGill University, Medical Physics Unit, Montreal, Canada; Maastricht University, Dept. of Precision Medicine, Maastricht, The Netherlands.
Purpose:
Radiomic texture calculation requires discretizing image intensities within the region-of-interest. FBN (fixed-bin-number), FBS (fixed-bin-size) and FBN and FBS with intensity equalization (FBNequal, FBSequal) are four discretization approaches. A crucial choice is the voxel intensity (Hounsfield units, or HU) binning range. We assessed the effect of this choice on radiomic features.
Methods:
The dataset comprised 95 patients with head-and-neck squamous-cell-carcinoma. Dual energy CT data was reconstructed at 21 electron energies (40, 45,… 140 keV). Each of 94 texture features were calculated with 64 extraction parameters. All features were calculated five times: original choice, left shift (-10/-20 HU), right shift (+10/+20 HU). For each feature, Spearman correlation between nominal and four variants were calculated to determine feature stability. This was done for six texture feature types (GLCM, GLRLM, GLSZM, GLDZM, NGTDM, and NGLDM) separately. This analysis was repeated for the four binning algorithms. Effect of feature instability on predictive ability was studied for lymphadenopathy as endpoint.
Results:
FBN and FBNequal algorithms showed good stability (correlation values consistently >0.9). For FBS and FBSequal algorithms, while median values exceeded 0.9, the 95% lower bound decreased as a function of energy, with poor performance over the entire spectrum. FBNequal was the most stable algorithm, and FBS the least.
Conclusions:
We believe this is the first multi-energy systematic study of the impact of CT HU range used during intensity discretization for radiomic feature extraction. Future analyses should account for this source of uncertainty when evaluating the robustness of their radiomic signature.
More Related Videos
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT