Related Experiment Video
Updated: Oct 26, 2025

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
UV radiation dose in real time with a cryogenic SiPM using Monte Carlo-Geant4 simulation
Maritza Delgado González1, Deywis Moreno Lopez2
1Research Center in Basic and Applied Sciences, Universidad Antonio Nariño, Bogotá, Colombia.
A new simulation method uses Geant4 and cryogenic Silicon PhotoMultipliers (SiPM) to measure UV radiation dose during liquid nitrogen sterilization. This allows for real-time quality control and certification of microorganism absence.
Area of Science:
- Physics
- Radiation Science
- Biotechnology
Background:
- Current liquid nitrogen sterilization lacks validated methods for UV radiation dose calculation.
- Quality control regulations require precise monitoring of sterilization processes.
Purpose of the Study:
- To develop a real-time method for calculating UV radiation dose in liquid nitrogen.
- To enable compliance with quality control regulations for LN2 sterilization.
- To validate the effectiveness of UV sterilization for eliminating microorganisms.
Main Methods:
- Utilized Geant4 simulation software for UV radiation transport modeling.
- Employed cryogenic Silicon PhotoMultipliers (SiPM) for in-situ radiation detection within liquid nitrogen.
- Identified the zone of minimum UV radiation within the LN2 container.
Main Results:
- Successfully simulated UV radiation dose distribution in liquid nitrogen.
- Estimated radiation dose using a cryogenic SiPM positioned in the minimum radiation zone.
- Demonstrated a method for real-time UV dose monitoring.
Conclusions:
- The developed simulation and detection method allows for accurate UV radiation dose calculation during LN2 sterilization.
- Real-time monitoring with cryogenic SiPMs in the minimum radiation zone can certify the absence of microorganisms.
- This approach addresses a critical gap in quality control for LN2-based sterilization processes.