Quality assurance data for regional drip-and-ship strategies- gearing up the transfer process
Erendira G Boss1, Ferdinand O Bohmann2, Björn Misselwitz3
1Department of Neurology, University Hospital Frankfurt, Frankfurt, Germany. erendira.boss@kgu.de.
Background:
Stroke patients with large vessel occlusion (LVO) require endovascular therapy (EVT) provided by comprehensive stroke centers (CSC). One strategy to achieve fast stroke symptom 'onset to treatment' times (OTT) is the preclinical selection of patients with severe stroke for direct transport to CSC. Another is the optimization of interhospital transfer workflow. Our aim was to investigate the dynamics of the OTT of 'drip-and-ship' patients as well as the current 'door-in-door-out' time (DIDO) and its determinants at representative regional German stroke units.
Methods:
We determined the numbers of all EVT treatments, 'drip-and-ship' and 'direct-to-center' patients and their median OTT from the mandatory quality assurance registry of the federal state of Hesse, Germany (2012-2019). Additionally, we captured process time stamps from primary stroke centers (PSC) in a consecutive registry of patients referred for EVT in our regional stroke network over a 3 months period.
Results:
Along with an increase of the EVT rate, the proportion of drip-and-ship patients grew steadily from 19.4% in 2012 to 31.3% in 2019. The time discrepancy for the median OTT between 'drip-and-ship' and 'direct-to-center' patients continuously declined from 173 to 74 min. The largest share of the DIDO (median 92, IQR 69-110) is spent with the organization of EVT and consecutive patient transfer.
Conclusions:
'Drip-and-ship' patients are an important and growing proportion of stroke patients undergoing EVT. The discrepancy in OTT for EVT between 'drip-and-ship' and 'direct-to-center' patients has been reduced considerably. Further optimization of the DIDO primarily aiming at the processes after the detection of LVO is urgently needed to improve stroke patient care.
More Related Videos
14:45Enumeration of Major Peripheral Blood Leukocyte Populations for Multicenter Clinical Trials Using a Whole Blood Phenotyping Assay
Published on: September 16, 2012
09:07Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
Published on: May 24, 2024
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Distribution Reliability and Automation
In Vitro Drug Release Testing: Overview, Development and Validation
Design Example: Aggregate Gradation
The grading, or particle-size distribution, of sand is determined using sieve analysis, with standard sizes ranging from 150 μm to 10 mm (ASTM No. 100 sieve to 3⁄8 in. sieve). Sand is...
Data Validation
Key parameters for method validation include: